What are the requirements for using bench top fume hoods in a cleanroom?
Oct 02, 2025
What are the requirements for using bench top fume hoods in a cleanroom?
As a dedicated supplier of bench top fume hoods, I've witnessed firsthand the crucial role these devices play in cleanroom environments. Cleanrooms are highly controlled spaces designed to minimize the presence of airborne particles, contaminants, and other pollutants. Bench top fume hoods, in this context, are essential for ensuring the safety of personnel and the integrity of sensitive processes. In this blog, I'll delve into the key requirements for using bench top fume hoods in a cleanroom.
Airflow and Ventilation
One of the primary requirements for using bench top fume hoods in a cleanroom is proper airflow and ventilation. The fume hood must be capable of maintaining a consistent and uniform airflow across the work surface to effectively capture and remove hazardous fumes, vapors, and particles. This is typically achieved through a combination of supply and exhaust air systems.
The supply air system provides fresh, filtered air into the fume hood, creating a positive pressure environment that prevents the ingress of contaminants from the surrounding cleanroom. The exhaust air system, on the other hand, removes the contaminated air from the fume hood and discharges it safely outside the building.
To ensure optimal airflow and ventilation, the fume hood should be designed with a suitable face velocity. Face velocity refers to the speed at which air enters the fume hood through the opening at the front. In a cleanroom setting, a face velocity of between 0.4 and 0.6 m/s is generally recommended. This range provides a balance between effective capture of contaminants and minimizing the risk of disturbing the cleanroom environment.
It's also important to regularly monitor and maintain the airflow and ventilation systems of the fume hood. This includes checking the air filters, ductwork, and fans for any signs of damage or blockage. Regular calibration of the airflow sensors and controls is also necessary to ensure accurate and reliable operation.


Filtration
In addition to proper airflow and ventilation, bench top fume hoods in a cleanroom must be equipped with high - efficiency filtration systems. These filters are designed to remove particles, microorganisms, and other contaminants from the air before it is either recirculated within the fume hood or discharged outside.
The most commonly used filters in fume hoods are High - Efficiency Particulate Air (HEPA) filters and Ultra - Low Particulate Air (ULPA) filters. HEPA filters are capable of removing at least 99.97% of particles that are 0.3 micrometers in diameter or larger, while ULPA filters can remove up to 99.999% of particles as small as 0.12 micrometers.
The choice of filter depends on the specific requirements of the cleanroom and the nature of the contaminants being handled. For general cleanroom applications, HEPA filters are often sufficient. However, in environments where extremely low levels of particles are required, such as in semiconductor manufacturing or pharmaceutical research, ULPA filters may be necessary.
It's crucial to replace the filters at regular intervals to maintain their effectiveness. The frequency of filter replacement depends on factors such as the usage of the fume hood, the type of contaminants present, and the manufacturer's recommendations. A clogged or dirty filter can reduce the airflow and ventilation efficiency of the fume hood, leading to increased levels of contaminants in the cleanroom.
Material Compatibility
When using bench top fume hoods in a cleanroom, it's essential to ensure that all the materials used in the construction of the fume hood are compatible with the chemicals and substances being handled. This includes the interior surfaces, shelves, worktops, and any other components that come into contact with the contaminants.
Incompatible materials can react with the chemicals, leading to corrosion, degradation, or the release of additional contaminants into the cleanroom environment. For example, some plastics may dissolve or swell when exposed to certain solvents, while metals may corrode in the presence of acids or alkalis.
To avoid these issues, the fume hood should be constructed from materials that are resistant to the specific chemicals being used. Common materials for fume hood construction include stainless steel, polypropylene, and phenolic resin. These materials offer excellent chemical resistance and are easy to clean and maintain.
Before installing a fume hood in a cleanroom, it's advisable to consult with the chemical suppliers and the fume hood manufacturer to ensure that the materials are compatible with the intended applications.
Noise Level
Noise can be a significant issue in a cleanroom environment, as it can interfere with communication, concentration, and the accuracy of sensitive equipment. Therefore, bench top fume hoods should be designed to operate at a low noise level.
The noise level of a fume hood is typically measured in decibels (dB). In a cleanroom, a noise level of less than 60 dB is generally considered acceptable. To achieve this, the fume hood should be equipped with quiet fans and motors, and the ductwork should be designed to minimize air turbulence and noise transmission.
Regular maintenance of the fans and motors is also important to ensure that they continue to operate quietly. This includes lubricating the moving parts, tightening any loose connections, and replacing worn - out components.
Safety Features
Safety is of utmost importance when using bench top fume hoods in a cleanroom. The fume hood should be equipped with a range of safety features to protect the users and the cleanroom environment.
One of the key safety features is a sash interlock system. The sash is the movable window at the front of the fume hood. The sash interlock system ensures that the fume hood will not operate if the sash is not in the correct position. This helps to prevent the release of contaminants into the cleanroom when the fume hood is not properly configured.
Another important safety feature is an airflow alarm. This alarm will sound if the airflow in the fume hood drops below a certain level, indicating a potential problem with the ventilation system. This allows the users to take immediate action to address the issue and prevent the accumulation of contaminants in the fume hood.
In addition, the fume hood should be equipped with emergency stop buttons and fire suppression systems. The emergency stop buttons can be used to quickly shut down the fume hood in case of an emergency, while the fire suppression systems can help to extinguish any fires that may occur inside the fume hood.
Installation and Maintenance
Proper installation and maintenance of bench top fume hoods are essential for their safe and effective operation in a cleanroom. The fume hood should be installed by a qualified professional who has experience working in cleanroom environments.
During the installation process, it's important to ensure that the fume hood is properly aligned and leveled. The ductwork should be connected securely to the fume hood and the ventilation system, and all the electrical connections should be made in accordance with the relevant safety standards.
Regular maintenance of the fume hood is also crucial. This includes cleaning the interior surfaces, replacing the filters, checking the airflow and ventilation systems, and inspecting the safety features. A maintenance schedule should be established and followed to ensure that the fume hood is always in good working condition.
Conclusion
Using bench top fume hoods in a cleanroom requires careful consideration of several key requirements, including airflow and ventilation, filtration, material compatibility, noise level, safety features, and installation and maintenance. By ensuring that these requirements are met, you can create a safe and efficient working environment in your cleanroom.
If you're in the market for a bench top fume hood for your cleanroom, we're here to help. As a leading supplier of bench top fume hoods, we offer a wide range of products that are designed to meet the specific needs of cleanroom applications. We also provide professional installation and maintenance services to ensure that your fume hood operates at its best.
For more information about our Portable Fume Hood, Portable Fumehood, or Fume Cupboards For Schools, please feel free to contact us. We look forward to discussing your requirements and providing you with the best solutions for your cleanroom.
References
- ASHRAE Standard 110 - 2016. Method of Testing Performance of Laboratory Fume Hoods.
- ISO 14644 - 1:2015. Cleanrooms and associated controlled environments - Part 1: Classification of air cleanliness.
- NFPA 45 - 2015. Standard on Fire Protection for Laboratories Using Chemicals.